| Filter Media: | PES membrane + borosilicate microfibre |
| Upstream Supports: | Polypropylene |
| Downstream Supports: | Polypropylene |
| Core and Cage: | Polypropylene |
| End Caps: | Polypropylene |
Code |
Absolute Filtration rating in liquids |
Acceptable limit for pressure hold test* |
||
Nr1. 30" cartridge |
Nr8. 30" cartridge |
Test Pressure |
||
AR |
0.45 micron |
<0.10 bar |
<0.10 bar |
1.1 bar |
AM |
0.65 micron |
<0.12 bar |
<0.12 bar |
0.9 bar |
AF |
0.80 micron |
<0.12 bar |
<0.12 bar |
0.6 bar |
AE |
1.2 micron |
<0.12 bar
|
<0.12 bar |
0.5 bar |
| * The values are rleated to 5 minutes and are indicative as they depend on the housing volume upstream the filter element | ||||
Recommended Flow Rate l/h 10" cartridge
Code |
AP=0.1bar |
AR |
300 |
AM |
350 |
AF |
400 |
AE |
450 |
Bacterial Retention
Code |
Absolute Filtration Rating Micron |
Bacterial Retention for 10" cartridge |
AR |
0.45 |
>1010 Leuconostoc oenos |
AM |
0.65 |
>109 Leuconostoc oenos |
AF |
0.8 |
>1011 Saccharomyces cerevisiae |
AE |
1.2 |
>1010 Saccharomyces cerevisiae |